%PDF- %PDF-
Direktori : /lib/dracut/modules.d/99kdumpbase/ |
Current File : //lib/dracut/modules.d/99kdumpbase/module-setup.sh |
#!/bin/bash _save_kdump_netifs() { local _name if [[ -n $2 ]]; then _name=$2 else _name=$1 fi unique_netifs[$1]=$_name } _get_kdump_netifs() { echo -n "${!unique_netifs[@]}" } kdump_module_init() { if ! [[ -d "${initdir}/tmp" ]]; then mkdir -p "${initdir}/tmp" fi . /lib/kdump/kdump-lib.sh } check() { [[ $debug ]] && set -x #kdumpctl sets this explicitly if [ -z "$IN_KDUMP" ] || [ ! -f /etc/kdump.conf ] then return 1 fi return 0 } depends() { local _dep="base shutdown" kdump_module_init add_opt_module() { [[ " $omit_dracutmodules " != *\ $1\ * ]] && _dep="$_dep $1" } if is_squash_available; then add_opt_module squash else dwarning "Required modules to build a squashed kdump image is missing!" fi add_opt_module watchdog-modules if is_wdt_active; then add_opt_module watchdog fi if is_ssh_dump_target; then _dep="$_dep ssh-client" fi if is_lvm2_thinp_dump_target; then if grep -q lvmthinpool-monitor <<< $(dracut --list-modules); then add_opt_module lvmthinpool-monitor else dwarning "Required lvmthinpool-monitor modules is missing! Please upgrade dracut >= 057." fi fi if [ "$(uname -m)" = "s390x" ]; then _dep="$_dep znet" fi if [ -n "$( find /sys/devices -name drm )" ] || [ -d /sys/module/hyperv_fb ]; then add_opt_module drm fi if is_generic_fence_kdump || is_pcs_fence_kdump; then _dep="$_dep network" fi echo $_dep } kdump_is_bridge() { [ -d /sys/class/net/"$1"/bridge ] } kdump_is_bond() { [ -d /sys/class/net/"$1"/bonding ] } kdump_is_team() { [ -f /usr/bin/teamnl ] && teamnl $1 ports &> /dev/null } kdump_is_vlan() { [ -f /proc/net/vlan/"$1" ] } # $1: netdev name source_ifcfg_file() { local ifcfg_file ifcfg_file=$(get_ifcfg_filename $1) if [ -f "${ifcfg_file}" ]; then . ${ifcfg_file} else dwarning "The ifcfg file of $1 is not found!" fi } add_dns_netdev() { local _server _route _server=$1 _route=`/sbin/ip -o route get to $_server 2>&1` [ $? != 0 ] && echo "DNS server $_server unreachable" _netdev=$(get_ip_route_field "$_route" "dev") _save_kdump_netifs "$_netdev" "$(kdump_setup_ifname $_netdev)" } # $1: netdev name kdump_setup_dns() { local _nameserver _dns local _dnsfile=${initdir}/etc/cmdline.d/42dns.conf source_ifcfg_file $1 [ -n "$DNS1" ] && echo "nameserver=$DNS1" > "$_dnsfile" && add_dns_netdev "$DNS1" [ -n "$DNS2" ] && echo "nameserver=$DNS2" >> "$_dnsfile" && add_dns_netdev "$DNS2" while read content; do _nameserver=$(echo $content | grep ^nameserver) [ -z "$_nameserver" ] && continue _dns=$(echo $_nameserver | cut -d' ' -f2) [ -z "$_dns" ] && continue if [ ! -f $_dnsfile ] || [ ! $(cat $_dnsfile | grep -q $_dns) ]; then echo "nameserver=$_dns" >> "$_dnsfile" add_dns_netdev "$_dns" fi done < "/etc/resolv.conf" } # $1: repeat times # $2: string to be repeated # $3: separator repeatedly_join_str() { local _count="$1" local _str="$2" local _separator="$3" local i _res if [[ "$_count" -le 0 ]]; then echo -n "" return fi i=0 _res="$_str" ((_count--)) while [[ "$i" -lt "$_count" ]]; do ((i++)) _res="${_res}${_separator}${_str}" done echo -n "$_res" } # $1: prefix # $2: ipv6_flag="-6" indicates it's IPv6 # Given a prefix, calculate the netmask (equivalent of "ipcalc -m") # by concatenating three parts, # 1) the groups with all bits set 1 # 2) a group with partial bits set to 0 # 3) the groups with all bits set to 0 cal_netmask_by_prefix() { local _prefix="$1" local _ipv6_flag="$2" _ipv6 local _bits_per_octet=8 local _count _res _octets_per_group _octets_total _seperator _total_groups local _max_group_value _max_group_value_repr _bits_per_group _tmp _zero_bits if [[ "$_ipv6_flag" == "-6" ]]; then _ipv6=1 else _ipv6=0 fi if [[ "$_prefix" -lt 0 || "$_prefix" -gt 128 ]] || \ ( ((!_ipv6)) && [[ "$_prefix" -gt 32 ]] ); then derror "Bad prefix:$_prefix for calculating netmask" exit 1 fi if ((_ipv6)); then _octets_per_group=2 _octets_total=16 _seperator=":" else _octets_per_group=1 _octets_total=4 _seperator="." fi _total_groups=$((_octets_total/_octets_per_group)) _bits_per_group=$((_octets_per_group * _bits_per_octet)) _max_group_value=$(((1 << _bits_per_group) - 1)) if ((_ipv6)); then _max_group_value_repr=$(printf "%x" $_max_group_value) else _max_group_value_repr="$_max_group_value" fi _count=$((_prefix/_octets_per_group/_bits_per_octet)) _first_part=$(repeatedly_join_str "$_count" "$_max_group_value_repr" "$_seperator") _res="$_first_part" _tmp=$((_octets_total*_bits_per_octet-_prefix)) _zero_bits=$(expr $_tmp % $_bits_per_group) if [[ "$_zero_bits" -ne 0 ]]; then _second_part=$((_max_group_value >> _zero_bits << _zero_bits)) if ((_ipv6)); then _second_part=$(printf "%x" $_second_part) fi ((_count++)) if [[ -z "$_first_part" ]]; then _res="$_second_part" else _res="${_first_part}${_seperator}${_second_part}" fi fi _count=$((_total_groups-_count)) if [[ "$_count" -eq 0 ]]; then echo -n "$_res" return fi if ((_ipv6)) && [[ "$_count" -gt 1 ]] ; then # use condensed notion for IPv6 _third_part=":" else _third_part=$(repeatedly_join_str "$_count" "0" "$_seperator") fi if [[ -z "$_res" ]] && ((!_ipv6)) ; then echo -n "${_third_part}" else echo -n "${_res}${_seperator}${_third_part}" fi } #$1: netdev name #$2: srcaddr #if it use static ip echo it, or echo null kdump_static_ip() { local _netdev="$1" _srcaddr="$2" kdumpnic="$3" _ipv6_flag local _netmask _gateway _ipaddr _target _nexthop _prefix _ipaddr=$(ip addr show dev $_netdev permanent | awk "/ $_srcaddr\/.* /{print \$2}") if is_ipv6_address $_srcaddr; then _ipv6_flag="-6" fi if [ -n "$_ipaddr" ]; then _gateway=$(ip $_ipv6_flag route list dev $_netdev | \ awk '/^default /{print $3}' | head -n 1) if [ "x" != "x"$_ipv6_flag ]; then # _ipaddr="2002::56ff:feb6:56d5/64", _netmask is the number after "/" _netmask=${_ipaddr#*\/} _srcaddr="[$_srcaddr]" _gateway="[$_gateway]" else _prefix=$(cut -d'/' -f2 <<< "$_ipaddr") _netmask=$(cal_netmask_by_prefix "$_prefix" "$_ipv6_flag") if [[ "$?" -ne 0 ]]; then derror "Failed to calculate netmask for $_ipaddr" exit 1 fi fi echo -n "${_srcaddr}::${_gateway}:${_netmask}::" fi /sbin/ip $_ipv6_flag route show | grep -v default | grep ".*via.* $_netdev " |\ while read _route; do _target=`echo $_route | cut -d ' ' -f1` _nexthop=`echo $_route | cut -d ' ' -f3` if [ "x" != "x"$_ipv6_flag ]; then _target="[$_target]" _nexthop="[$_nexthop]" fi echo "rd.route=$_target:$_nexthop:$kdumpnic" done >> ${initdir}/etc/cmdline.d/45route-static.conf } kdump_get_mac_addr() { cat /sys/class/net/$1/address } #Bonding or team master modifies the mac address #of its slaves, we should use perm address kdump_get_perm_addr() { local addr=$(ethtool -P $1 | sed -e 's/Permanent address: //') if [ -z "$addr" ] || [ "$addr" = "00:00:00:00:00:00" ] then derror "Can't get the permanent address of $1" else echo "$addr" fi } # Prefix kernel assigned names with "kdump-". EX: eth0 -> kdump-eth0 # Because kernel assigned names are not persistent between 1st and 2nd # kernel. We could probably end up with eth0 being eth1, eth0 being # eth1, and naming conflict happens. kdump_setup_ifname() { local _ifname # If ifname already has 'kdump-' prefix, we must be switching from # fadump to kdump. Skip prefixing 'kdump-' in this case as adding # another prefix may truncate the ifname. Since an ifname with # 'kdump-' is already persistent, this should be fine. if [[ $1 =~ ^eth.* ]] && [[ ! $1 =~ ^kdump-* ]]; then _ifname="kdump-$1" else _ifname="$1" fi echo "$_ifname" } kdump_install_nm_netif_allowlist() { local _netif _except_netif _netif_allowlist _netif_allowlist_nm_conf for _netif in $1; do _per_mac=$(kdump_get_perm_addr "$_netif") if [[ "$_per_mac" != 'not set' ]]; then _except_netif="mac:$_per_mac" else _except_netif="interface-name:${unique_netifs[${_netif}]}" fi _netif_allowlist="${_netif_allowlist}except:${_except_netif};" done _netif_allowlist_nm_conf=${initdir}/tmp/netif_allowlist_nm_conf cat << EOF > "$_netif_allowlist_nm_conf" [device-others] match-device=${_netif_allowlist} managed=false EOF inst "$_netif_allowlist_nm_conf" "/etc/NetworkManager/conf.d/10-kdump-netif_allowlist.conf" rm -f "$_netif_allowlist_nm_conf" } _get_nic_driver() { ethtool -i "$1" | sed -n -E "s/driver: (.*)/\1/p" } _get_hpyerv_physical_driver() { local _physical_nic _physical_nic=$(find /sys/class/net/"$1"/ -name 'lower_*' | sed -En "s/\/.*lower_(.*)/\1/p") [[ -n $_physical_nic ]] || return _get_nic_driver "$_physical_nic" } kdump_install_nic_driver() { local _netif _driver _drivers _drivers=() for _netif in $1; do [[ $_netif == lo ]] && continue _driver=$(_get_nic_driver "$_netif") if [[ -z $_driver ]]; then derror "Failed to get the driver of $_netif" exit 1 fi if [[ $_driver == "802.1Q VLAN Support" ]]; then # ethtool somehow doesn't return the driver name for a VLAN NIC _driver=8021q elif [[ $_driver == "team" ]]; then # install the team mode drivers like team_mode_roundrobin.ko as well _driver='=drivers/net/team' elif [[ $_driver == "hv_netvsc" ]]; then # A Hyper-V VM may have accelerated networking # https://learn.microsoft.com/en-us/azure/virtual-network/accelerated-networking-overview # Install the driver of physical NIC as well _drivers+=("$(_get_hpyerv_physical_driver "$_netif")") fi _drivers+=("$_driver") done [[ -n ${_drivers[*]} ]] || return instmods "${_drivers[@]}" } kdump_setup_bridge() { local _netdev=$1 local _brif _dev _mac _kdumpdev for _dev in `ls /sys/class/net/$_netdev/brif/`; do _kdumpdev="" if kdump_is_bond "$_dev"; then kdump_setup_bond "$_dev" elif kdump_is_team "$_dev"; then kdump_setup_team "$_dev" elif kdump_is_vlan "$_dev"; then kdump_setup_vlan "$_dev" else _mac=$(kdump_get_mac_addr $_dev) _kdumpdev=$(kdump_setup_ifname $_dev) echo -n " ifname=$_kdumpdev:$_mac" >> ${initdir}/etc/cmdline.d/41bridge.conf fi _save_kdump_netifs "$_dev" "$_kdumpdev" [[ -z $_kdumpdev ]] && _kdumpdev=$_dev _brif+="$_kdumpdev," done echo " bridge=$_netdev:$(echo $_brif | sed -e 's/,$//')" >> ${initdir}/etc/cmdline.d/41bridge.conf } kdump_setup_bond() { local _netdev=$1 local _dev _mac _slaves _kdumpdev for _dev in `cat /sys/class/net/$_netdev/bonding/slaves`; do _mac=$(kdump_get_perm_addr $_dev) _kdumpdev=$(kdump_setup_ifname $_dev) _save_kdump_netifs "$_dev" "$_kdumpdev" echo -n " ifname=$_kdumpdev:$_mac" >> ${initdir}/etc/cmdline.d/42bond.conf _slaves+="$_kdumpdev," done echo -n " bond=$_netdev:$(echo $_slaves | sed 's/,$//')" >> ${initdir}/etc/cmdline.d/42bond.conf # Get bond options specified in ifcfg source_ifcfg_file $_netdev bondoptions=":$(echo $BONDING_OPTS | xargs echo | tr " " ",")" echo "$bondoptions" >> ${initdir}/etc/cmdline.d/42bond.conf } kdump_setup_team() { local _netdev=$1 local _dev _mac _slaves _kdumpdev for _dev in `teamnl $_netdev ports | awk -F':' '{print $2}'`; do _mac=$(kdump_get_perm_addr $_dev) _kdumpdev=$(kdump_setup_ifname $_dev) _save_kdump_netifs "$_dev" "$_kdumpdev" echo -n " ifname=$_kdumpdev:$_mac" >> ${initdir}/etc/cmdline.d/44team.conf _slaves+="$_kdumpdev," done echo " team=$_netdev:$(echo $_slaves | sed -e 's/,$//')" >> ${initdir}/etc/cmdline.d/44team.conf #Buggy version teamdctl outputs to stderr! #Try to use the latest version of teamd. teamdctl "$_netdev" config dump > ${initdir}/tmp/$$-$_netdev.conf if [ $? -ne 0 ] then derror "teamdctl failed." exit 1 fi inst_dir /etc/teamd inst_simple ${initdir}/tmp/$$-$_netdev.conf "/etc/teamd/$_netdev.conf" rm -f ${initdir}/tmp/$$-$_netdev.conf } kdump_setup_vlan() { local _netdev=$1 local _phydev="$(awk '/^Device:/{print $2}' /proc/net/vlan/"$_netdev")" local _netmac="$(kdump_get_mac_addr $_phydev)" local _kdumpdev #Just support vlan over bond and team if kdump_is_bridge "$_phydev"; then derror "Vlan over bridge is not supported!" exit 1 elif kdump_is_bond "$_phydev"; then kdump_setup_bond "$_phydev" echo " vlan=$(kdump_setup_ifname $_netdev):$_phydev" > ${initdir}/etc/cmdline.d/43vlan.conf else _kdumpdev="$(kdump_setup_ifname $_phydev)" echo " vlan=$(kdump_setup_ifname $_netdev):$_kdumpdev ifname=$_kdumpdev:$_netmac" > ${initdir}/etc/cmdline.d/43vlan.conf fi _save_kdump_netifs "$_phydev" "$_kdumpdev" } # find online znet device # return ifname (_netdev) # code reaped from the list_configured function of # https://github.com/hreinecke/s390-tools/blob/master/zconf/znetconf find_online_znet_device() { local CCWGROUPBUS_DEVICEDIR="/sys/bus/ccwgroup/devices" local NETWORK_DEVICES d ifname ONLINE [ ! -d "$CCWGROUPBUS_DEVICEDIR" ] && return NETWORK_DEVICES=$(find $CCWGROUPBUS_DEVICEDIR) for d in $NETWORK_DEVICES do [ ! -f "$d/online" ] && continue read ONLINE < $d/online if [ $ONLINE -ne 1 ]; then continue fi # determine interface name, if there (only for qeth and if # device is online) if [ -f $d/if_name ] then read ifname < $d/if_name elif [ -d $d/net ] then ifname=$(ls $d/net/) fi [ -n "$ifname" ] && break done echo -n "$ifname" } # setup s390 znet cmdline # $1: netdev name kdump_setup_znet() { local _options="" local _netdev=$1 source_ifcfg_file $_netdev [[ -z "$NETTYPE" ]] && return [[ -z "$SUBCHANNELS" ]] && return for i in $OPTIONS; do _options=${_options},$i done echo rd.znet=${NETTYPE},${SUBCHANNELS}${_options} rd.znet_ifname=$(kdump_setup_ifname $_netdev):${SUBCHANNELS} > ${initdir}/etc/cmdline.d/30znet.conf } _get_nic_driver() { ethtool -i "$1" | sed -n -E "s/driver: (.*)/\1/p" } _rename_hypver_netdev() { local _udev_rule_dir _udev_rule_dir=${initdir}/etc/udev/rules.d mkdir -p "$_udev_rule_dir" printf 'SUBSYSTEM=="net", ACTION=="add", DRIVERS=="hv_netvsc", ATTR{address}=="%s", ATTR{type}=="1", NAME="%s"\n' "$2" "$1" > "${_udev_rule_dir}/80-hv_netvsc-ifname.rules" } # Setup dracut to bringup a given network interface kdump_setup_netdev() { local _netdev=$1 _srcaddr=$2 local _static _proto _ip_conf _ip_opts _ifname_opts kdumpnic local _netmac=$(kdump_get_mac_addr $_netdev) local _znet_netdev kdumpnic=$(kdump_setup_ifname $_netdev) _znet_netdev=$(find_online_znet_device) if [[ -n "$_znet_netdev" ]]; then $(kdump_setup_znet "$_znet_netdev") if [[ $? != 0 ]]; then derror "Failed to set up znet" exit 1 fi fi _static=$(kdump_static_ip $_netdev $_srcaddr $kdumpnic) if [ -n "$_static" ]; then _proto=none elif is_ipv6_address $_srcaddr; then _proto=auto6 else _proto=dhcp fi _ip_conf="${initdir}/etc/cmdline.d/40ip.conf" _ip_opts=" ip=${_static}$kdumpnic:${_proto}" # dracut doesn't allow duplicated configuration for same NIC, even they're exactly the same. # so we have to avoid adding duplicates # We should also check /proc/cmdline for existing ip=xx arg. # For example, iscsi boot will specify ip=xxx arg in cmdline. if [ ! -f $_ip_conf ] || ! grep -q $_ip_opts $_ip_conf &&\ ! grep -q "ip=[^[:space:]]*$_netdev" /proc/cmdline; then echo "$_ip_opts" >> $_ip_conf fi if kdump_is_bridge "$_netdev"; then kdump_setup_bridge "$_netdev" elif kdump_is_bond "$_netdev"; then kdump_setup_bond "$_netdev" elif kdump_is_team "$_netdev"; then kdump_setup_team "$_netdev" elif kdump_is_vlan "$_netdev"; then kdump_setup_vlan "$_netdev" else if [[ $(_get_nic_driver "$1") != hv_netvsc ]]; then _ifname_opts=" ifname=$kdumpnic:$_netmac" echo "$_ifname_opts" >> $_ip_conf else _rename_hypver_netdev "$kdumpnic" "$_netmac" fi fi _save_kdump_netifs "$_netdev" "$_kdumpdev" kdump_setup_dns "$_netdev" if [ ! -f ${initdir}/etc/cmdline.d/50neednet.conf ]; then # network-manager module needs this parameter echo "rd.neednet" >> ${initdir}/etc/cmdline.d/50neednet.conf fi } get_ip_route_field() { if `echo $1 | grep -q $2`; then echo ${1##*$2} | cut -d ' ' -f1 fi } #Function:kdump_install_net #$1: config values of net line in kdump.conf #$2: srcaddr of network device kdump_install_net() { local _server _netdev _srcaddr _route _serv_tmp local config_val="$1" _server=$(get_remote_host $config_val) if is_hostname $_server; then _serv_tmp=`getent ahosts $_server | grep -v : | head -n 1` if [ -z "$_serv_tmp" ]; then _serv_tmp=`getent ahosts $_server | head -n 1` fi _server=`echo $_serv_tmp | cut -d' ' -f1` fi _route=`/sbin/ip -o route get to $_server 2>&1` [ $? != 0 ] && echo "Bad kdump location: $config_val" && exit 1 #the field in the ip output changes if we go to another subnet _srcaddr=$(get_ip_route_field "$_route" "src") _netdev=$(get_ip_route_field "$_route" "dev") kdump_setup_netdev "${_netdev}" "${_srcaddr}" #save netdev used for kdump as cmdline # Whoever calling kdump_install_net() is setting up the default gateway, # ie. bootdev/kdumpnic. So don't override the setting if calling # kdump_install_net() for another time. For example, after setting eth0 as # the default gate way for network dump, eth1 in the fence kdump path will # call kdump_install_net again and we don't want eth1 to be the default # gateway. if [ ! -f ${initdir}/etc/cmdline.d/60kdumpnic.conf ] && [ ! -f ${initdir}/etc/cmdline.d/70bootdev.conf ]; then echo "kdumpnic=$(kdump_setup_ifname $_netdev)" > ${initdir}/etc/cmdline.d/60kdumpnic.conf echo "bootdev=$(kdump_setup_ifname $_netdev)" > ${initdir}/etc/cmdline.d/70bootdev.conf fi } # install etc/kdump/pre.d and /etc/kdump/post.d kdump_install_pre_post_conf() { if [ -d /etc/kdump/pre.d ]; then for file in /etc/kdump/pre.d/*; do if [ -x "$file" ]; then dracut_install $file elif [ $file != "/etc/kdump/pre.d/*" ]; then echo "$file is not executable" fi done fi if [ -d /etc/kdump/post.d ]; then for file in /etc/kdump/post.d/*; do if [ -x "$file" ]; then dracut_install $file elif [ $file != "/etc/kdump/post.d/*" ]; then echo "$file is not executable" fi done fi } default_dump_target_install_conf() { local _target _fstype local _mntpoint _save_path is_user_configured_dump_target && return _save_path=$(get_bind_mount_source $(get_save_path)) _target=$(get_target_from_path $_save_path) _mntpoint=$(get_mntpoint_from_target $_target) _fstype=$(get_fs_type_from_target $_target) if is_fs_type_nfs $_fstype; then kdump_install_net "$_target" _fstype="nfs" else _target=$(kdump_get_persistent_dev $_target) fi echo "$_fstype $_target" >> ${initdir}/tmp/$$-kdump.conf # don't touch the path under root mount if [ "$_mntpoint" != "/" ]; then _save_path=${_save_path##"$_mntpoint"} fi #erase the old path line, then insert the parsed path sed -i "/^path/d" ${initdir}/tmp/$$-kdump.conf echo "path $_save_path" >> ${initdir}/tmp/$$-kdump.conf } #install kdump.conf and what user specifies in kdump.conf kdump_install_conf() { local _opt _val _pdev sed -ne '/^#/!p' /etc/kdump.conf > ${initdir}/tmp/$$-kdump.conf while read _opt _val; do # remove inline comments after the end of a directive. case "$_opt" in raw) _pdev=$(persistent_policy="by-id" kdump_get_persistent_dev $_val) sed -i -e "s#^$_opt[[:space:]]\+$_val#$_opt $_pdev#" ${initdir}/tmp/$$-kdump.conf ;; ext[234]|xfs|btrfs|minix) _pdev=$(kdump_get_persistent_dev $_val) sed -i -e "s#^$_opt[[:space:]]\+$_val#$_opt $_pdev#" ${initdir}/tmp/$$-kdump.conf ;; ssh|nfs) kdump_install_net "$_val" ;; dracut_args) if [[ $(get_dracut_args_fstype "$_val") = nfs* ]] ; then kdump_install_net "$(get_dracut_args_target "$_val")" fi ;; kdump_pre|kdump_post|extra_bins) dracut_install $_val ;; core_collector) dracut_install "${_val%%[[:blank:]]*}" ;; esac done <<< "$(read_strip_comments /etc/kdump.conf)" kdump_install_pre_post_conf default_dump_target_install_conf kdump_configure_fence_kdump "${initdir}/tmp/$$-kdump.conf" inst "${initdir}/tmp/$$-kdump.conf" "/etc/kdump.conf" rm -f ${initdir}/tmp/$$-kdump.conf } # Default sysctl parameters should suffice for kdump kernel. # Remove custom configurations sysctl.conf & sysctl.d/* remove_sysctl_conf() { # As custom configurations like vm.min_free_kbytes can lead # to OOM issues in kdump kernel, avoid them rm -f "${initdir}/etc/sysctl.conf" rm -rf "${initdir}/etc/sysctl.d" rm -rf "${initdir}/run/sysctl.d" rm -rf "${initdir}/usr/lib/sysctl.d" } kdump_iscsi_get_rec_val() { local result # The open-iscsi 742 release changed to using flat files in # /var/lib/iscsi. result=$(/sbin/iscsiadm --show -m session -r ${1} | grep "^${2} = ") result=${result##* = } echo $result } kdump_get_iscsi_initiator() { local _initiator local initiator_conf="/etc/iscsi/initiatorname.iscsi" [ -f "$initiator_conf" ] || return 1 while read _initiator; do [ -z "${_initiator%%#*}" ] && continue # Skip comment lines case $_initiator in InitiatorName=*) initiator=${_initiator#InitiatorName=} echo "rd.iscsi.initiator=${initiator}" return 0;; *) ;; esac done < ${initiator_conf} return 1 } # Figure out iBFT session according to session type is_ibft() { [ "$(kdump_iscsi_get_rec_val $1 "node.discovery_type")" = fw ] } kdump_setup_iscsi_device() { local path=$1 local tgt_name; local tgt_ipaddr; local username; local password; local userpwd_str; local username_in; local password_in; local userpwd_in_str; local netdev local srcaddr local idev local netroot_str ; local initiator_str; local netroot_conf="${initdir}/etc/cmdline.d/50iscsi.conf" local initiator_conf="/etc/iscsi/initiatorname.iscsi" dinfo "Found iscsi component $1" # Check once before getting explicit values, so we can bail out early, # e.g. in case of pure-hardware(all-offload) iscsi. if ! /sbin/iscsiadm -m session -r ${path} &>/dev/null ; then return 1 fi if is_ibft ${path}; then return fi # Remove software iscsi cmdline generated by 95iscsi, # and let kdump regenerate here. rm -f ${initdir}/etc/cmdline.d/95iscsi.conf tgt_name=$(kdump_iscsi_get_rec_val ${path} "node.name") tgt_ipaddr=$(kdump_iscsi_get_rec_val ${path} "node.conn\[0\].address") # get and set username and password details username=$(kdump_iscsi_get_rec_val ${path} "node.session.auth.username") [ "$username" == "<empty>" ] && username="" password=$(kdump_iscsi_get_rec_val ${path} "node.session.auth.password") [ "$password" == "<empty>" ] && password="" username_in=$(kdump_iscsi_get_rec_val ${path} "node.session.auth.username_in") [ -n "$username" ] && userpwd_str="$username:$password" # get and set incoming username and password details [ "$username_in" == "<empty>" ] && username_in="" password_in=$(kdump_iscsi_get_rec_val ${path} "node.session.auth.password_in") [ "$password_in" == "<empty>" ] && password_in="" [ -n "$username_in" ] && userpwd_in_str=":$username_in:$password_in" netdev=$(/sbin/ip route get to ${tgt_ipaddr} | \ sed 's|.*dev \(.*\).*|\1|g') srcaddr=$(echo $netdev | awk '{ print $3; exit }') netdev=$(echo $netdev | awk '{ print $1; exit }') kdump_setup_netdev $netdev $srcaddr # prepare netroot= command line # FIXME: Do we need to parse and set other parameters like protocol, port # iscsi_iface_name, netdev_name, LUN etc. if is_ipv6_address $tgt_ipaddr; then tgt_ipaddr="[$tgt_ipaddr]" fi netroot_str="netroot=iscsi:${userpwd_str}${userpwd_in_str}@$tgt_ipaddr::::$tgt_name" [[ -f $netroot_conf ]] || touch $netroot_conf # If netroot target does not exist already, append. if ! grep -q $netroot_str $netroot_conf; then echo $netroot_str >> $netroot_conf dinfo "Appended $netroot_str to $netroot_conf" fi # Setup initator initiator_str=$(kdump_get_iscsi_initiator) [ $? -ne "0" ] && derror "Failed to get initiator name" && return 1 # If initiator details do not exist already, append. if ! grep -q "$initiator_str" $netroot_conf; then echo "$initiator_str" >> $netroot_conf dinfo "Appended "$initiator_str" to $netroot_conf" fi } kdump_check_iscsi_targets () { # If our prerequisites are not met, fail anyways. type -P iscsistart >/dev/null || return 1 kdump_check_setup_iscsi() { local _dev _dev=$1 [[ -L /sys/dev/block/$_dev ]] || return cd "$(readlink -f /sys/dev/block/$_dev)" until [[ -d sys || -d iscsi_session ]]; do cd .. done [[ -d iscsi_session ]] && kdump_setup_iscsi_device "$PWD" } [[ $hostonly ]] || [[ $mount_needs ]] && { for_each_host_dev_and_slaves_all kdump_check_setup_iscsi } } # hostname -a is deprecated, do it by ourself get_alias() { local ips local entries local alias_set ips=$(hostname -I) for ip in $ips do # in /etc/hosts, alias can come at the 2nd column entries=$(grep $ip /etc/hosts | awk '{ $1=""; print $0 }') if [ $? -eq 0 ]; then alias_set="$alias_set $entries" fi done echo $alias_set } is_localhost() { local hostnames=$(hostname -A) local shortnames=$(hostname -A -s) local aliasname=$(get_alias) local nodename=$1 hostnames="$hostnames $shortnames $aliasname" for name in ${hostnames}; do if [ "$name" == "$nodename" ]; then return 0 fi done return 1 } # retrieves fence_kdump nodes from Pacemaker cluster configuration get_pcs_fence_kdump_nodes() { local nodes # get cluster nodes from cluster cib, get interface and ip address nodelist=`pcs cluster cib | xmllint --xpath "/cib/status/node_state/@uname" -` # nodelist is formed as 'uname="node1" uname="node2" ... uname="nodeX"' # we need to convert each to node1, node2 ... nodeX in each iteration for node in ${nodelist}; do # convert $node from 'uname="nodeX"' to 'nodeX' eval $node nodename=$uname # Skip its own node name if [ "$nodename" = `hostname` -o "$nodename" = `hostname -s` ]; then continue fi nodes="$nodes $nodename" done echo $nodes } # retrieves fence_kdump args from config file get_pcs_fence_kdump_args() { if [ -f $FENCE_KDUMP_CONFIG_FILE ]; then . $FENCE_KDUMP_CONFIG_FILE echo $FENCE_KDUMP_OPTS fi } get_generic_fence_kdump_nodes() { local filtered local nodes nodes=$(get_option_value "fence_kdump_nodes") for node in ${nodes}; do # Skip its own node name if is_localhost $node; then continue fi filtered="$filtered $node" done echo $filtered } # setup fence_kdump in cluster # setup proper network and install needed files kdump_configure_fence_kdump () { local kdump_cfg_file=$1 local nodes local args if is_generic_fence_kdump; then nodes=$(get_generic_fence_kdump_nodes) elif is_pcs_fence_kdump; then nodes=$(get_pcs_fence_kdump_nodes) # set appropriate options in kdump.conf echo "fence_kdump_nodes $nodes" >> ${kdump_cfg_file} args=$(get_pcs_fence_kdump_args) if [ -n "$args" ]; then echo "fence_kdump_args $args" >> ${kdump_cfg_file} fi else # fence_kdump not configured return 1 fi # setup network for each node for node in ${nodes}; do kdump_install_net $node done dracut_install /etc/hosts dracut_install /etc/nsswitch.conf dracut_install $FENCE_KDUMP_SEND } # Install a random seed used to feed /dev/urandom # By the time kdump service starts, /dev/uramdom is already fed by systemd kdump_install_random_seed() { local poolsize=`cat /proc/sys/kernel/random/poolsize` if [ ! -d ${initdir}/var/lib/ ]; then mkdir -p ${initdir}/var/lib/ fi dd if=/dev/urandom of=${initdir}/var/lib/random-seed \ bs=$poolsize count=1 2> /dev/null } remove_cpu_online_rule() { local file=${initdir}/usr/lib/udev/rules.d/40-redhat.rules sed -i '/SUBSYSTEM=="cpu"/d' $file } kdump_install_systemd_conf() { local failure_action=$(get_option_value "failure_action") # Kdump turns out to require longer default systemd mount timeout # than 1st kernel(90s by default), we use default 300s for kdump. grep -r "^[[:space:]]*DefaultTimeoutStartSec=" ${initdir}/etc/systemd/system.conf* &>/dev/null if [ $? -ne 0 ]; then mkdir -p ${initdir}/etc/systemd/system.conf.d echo "[Manager]" > ${initdir}/etc/systemd/system.conf.d/kdump.conf echo "DefaultTimeoutStartSec=300s" >> ${initdir}/etc/systemd/system.conf.d/kdump.conf fi # Forward logs to console directly, and don't read Kmsg, this avoids # unneccessary memory consumption and make console output more useful. # Only do so for non fadump image. mkdir -p ${initdir}/etc/systemd/journald.conf.d echo "[Journal]" > ${initdir}/etc/systemd/journald.conf.d/kdump.conf echo "Storage=volatile" >> ${initdir}/etc/systemd/journald.conf.d/kdump.conf echo "ReadKMsg=no" >> ${initdir}/etc/systemd/journald.conf.d/kdump.conf echo "ForwardToConsole=yes" >> ${initdir}/etc/systemd/journald.conf.d/kdump.conf } install() { declare -A unique_netifs local arch _netifs kdump_module_init kdump_install_conf remove_sysctl_conf # Onlining secondary cpus breaks kdump completely on KVM on Power hosts # Though we use maxcpus=1 by default but 40-redhat.rules will bring up all # possible cpus by default. (rhbz1270174 rhbz1266322) # Thus before we get the kernel fix and the systemd rule fix let's remove # the cpu online rule in kdump initramfs. arch=$(uname -m) if [[ "$arch" = "ppc64le" ]] || [[ "$arch" = "ppc64" ]]; then remove_cpu_online_rule fi if is_ssh_dump_target; then kdump_install_random_seed fi dracut_install -o /etc/adjtime /etc/localtime inst "$moddir/monitor_dd_progress" "/kdumpscripts/monitor_dd_progress" chmod +x ${initdir}/kdumpscripts/monitor_dd_progress inst "/bin/dd" "/bin/dd" inst "/bin/tail" "/bin/tail" inst "/bin/date" "/bin/date" inst "/bin/sync" "/bin/sync" inst "/bin/cut" "/bin/cut" inst "/bin/head" "/bin/head" inst "/sbin/makedumpfile" "/sbin/makedumpfile" inst "/sbin/vmcore-dmesg" "/sbin/vmcore-dmesg" inst "/usr/bin/printf" "/sbin/printf" inst "/usr/bin/logger" "/sbin/logger" inst "/usr/bin/chmod" "/sbin/chmod" inst "/lib/kdump/kdump-lib.sh" "/lib/kdump-lib.sh" inst "/lib/kdump/kdump-lib-initramfs.sh" "/lib/kdump-lib-initramfs.sh" inst "/lib/kdump/kdump-logger.sh" "/lib/kdump-logger.sh" inst "$moddir/kdump.sh" "/usr/bin/kdump.sh" inst "$moddir/kdump-capture.service" "$systemdsystemunitdir/kdump-capture.service" systemctl -q --root "$initdir" add-wants initrd.target kdump-capture.service inst "$moddir/kdump-error-handler.sh" "/usr/bin/kdump-error-handler.sh" inst "$moddir/kdump-error-handler.service" "$systemdsystemunitdir/kdump-error-handler.service" # Replace existing emergency service and emergency target cp "$moddir/kdump-emergency.service" "$initdir/$systemdsystemunitdir/emergency.service" cp "$moddir/kdump-emergency.target" "$initdir/$systemdsystemunitdir/emergency.target" # Also redirect dracut-emergency to kdump error handler ln_r "$systemdsystemunitdir/emergency.service" "$systemdsystemunitdir/dracut-emergency.service" # Check for all the devices and if any device is iscsi, bring up iscsi # target. Ideally all this should be pushed into dracut iscsi module # at some point of time. kdump_check_iscsi_targets _netifs=$(_get_kdump_netifs) if [[ -n "$_netifs" ]]; then kdump_install_nm_netif_allowlist "$_netifs" kdump_install_nic_driver "$_netifs" fi kdump_install_systemd_conf # For the lvm type target under kdump, in /etc/lvm/lvm.conf we can # safely replace "reserved_memory=XXXX"(default value is 8192) with # "reserved_memory=1024" to lower memory pressure under kdump. We do # it unconditionally here, if "/etc/lvm/lvm.conf" doesn't exist, it # actually does nothing. sed -i -e \ 's/\(^[[:space:]]*reserved_memory[[:space:]]*=\)[[:space:]]*[[:digit:]]*/\1 1024/' \ ${initdir}/etc/lvm/lvm.conf &>/dev/null # Skip initrd-cleanup.service and initrd-parse-etc.service becasue we don't # need to switch root. Instead of removing them, we use ConditionPathExists # to check if /proc/vmcore exists to determine if we are in kdump. sed -i '/\[Unit\]/a ConditionPathExists=!\/proc\/vmcore' \ "${initdir}/${systemdsystemunitdir}/initrd-cleanup.service" &> /dev/null sed -i '/\[Unit\]/a ConditionPathExists=!\/proc\/vmcore' \ "${initdir}/${systemdsystemunitdir}/initrd-parse-etc.service" &> /dev/null # Save more memory by dropping switch root capability dracut_no_switch_root }